DiskSpd
DiskSpd is a storage performance tool from the Windows, Windows Server and Cloud Server Infrastructure engineering teams at Microsoft. Please visit https://github.com/Microsoft/diskspd/wiki for updated documentation.
In addition to the tool itself, this repository hosts measurement frameworks which utilize DiskSpd. The initial example is VM Fleet, used for Windows Server Hyper-Converged environments with Storage Spaces Direct.
This project has adopted the Microsoft Open Source Code of Conduct. For more information see the Code of Conduct FAQ or contact [email protected] with any additional questions or comments.
Releases
The Releases page includes pre-compiled binaries (ZIP) and source code for the most current releases of the DiskSpd tool. The latest update to DiskSpd can always be downloaded from https://github.com/Microsoft/diskspd/releases/latest/download/DiskSpd.zip (aka https://aka.ms/getdiskspd).
What's New?
DISKSPD
DISKSPD 2.2 6/3/2024
NOTE: changes to the asynchronous IO loop will require rebaselining results with queue depths greater than 1.
The new design drains the completion queue more aggressively, shrinking delays that impacted latency measurement
especially on faster storage targeting higher queue depths. Latency measurement is improved at a very small cost
to rates, as well as improving rates when latency measurement is not used (-D
or -L
) due to batch dequeue.
Smaller IO sizes will see the most change.
- New: Socket, NUMA, Core and Power Efficiency Class (big/little cores) added to processor topology reporting (XML and text output)
- topology elements only displayed in text results when > 1 are present (e.g. multi-socket systems)
- CPU numbering remains group relative, as is the new Core numbering
- highest Power Efficiency Class is marked with a
P
suffix (this will usually be 1P
v. 0
)
- NOTE: efficiency classes can have major impact; work on heterogenous systems must be aware of core properties in combination with thread affinity rules (see
-a
and -n
)
- New: active power scheme reporting
- New: base target offset switch now allows range specification:
-Bbase[:length]
; replaces -B
and -f
- post-run latency histogram processing now significantly faster
- verbose output is more consistent; includes actual warmup, measured and cooldown intervals v. expected
Binary release supports down to Windows 8 and Windows Server 2012; now uses the Universal CRT.
DISKSPD 2.1 7/1/2021
- New
-gi
form allowing throughput limit specification in units of IOPS (per specified blocksize)
- New
-rs
to specify mixed random/sequential operation (pct random); geometric distribution of run lengths
- New
-rd
to specify non-uniform IO distributions across target
pct
by target percentage
abs
by absolute offset
- New
-Rp
to show specified parameter set in indicated profile output form; works with -X XML profiles and conventional command line
- XML results/profiles are now indented for ease of review
- Text result output updates
- now shows values in size units (K/M/G, and now TiB) to two decimals
- thread stride no longer shown unless specified
- -F/-O threadpool parameters shown
- XML profiles can now be built more generically
- XML profiles can be stated in terms of templated target names (*1, *2), replaced in order from command line invocation
- the command line now allows options alongside -X: -v, -z, -R and -W/-d/-C along with template target specs
DISKSPD 2.0.21a 9/21/2018
- Added support for memory mapped I/O:
- New
-Sm
option to enable memory mapped I/O
- New
-N
option to specify flush options for memory mapped I/O
- Added support for providing Event Tracing for Windows (ETW) events
- Included a Windows Performance Recorder (WPR) profile to enable ETW tracing
- Added system information to the ResultParser output
DISKSPD 2.0.20a 2/28/2018
- Changes that may require rebaselining of results:
- New random number generator that may show an observable decreased cost
- Switched to 512-byte aligned buffers with the
-Z
option to increase performance
- New
-O
option for specifying the number of outstanding IO requests per thread
- New
-Zr
option for per-IO randomization of write buffer content
- XML: Adds a new
element to support target weighting schemes
- Enhanced statistics captured from IOPS data
- Added support for validating XML profiles using an in-built XSD
- Added support for handling RAW volumes
- Updated CPU statistics to work on > 64-core systems
- Updated calculation and accuracy of CPU statistics
- Re-enable support for ETW statistics
DISKSPD 2.0.18a 5/31/2016
- update
/?
example to use -Sh
v. deprecated -h
- fix operation on volumes on GPT partitioned media (:)
- fix IO priority hint to proper stack alignment (if not 8 byte, will fail)
- use iB notation to clarify that text result output is in 2^n units (KiB/MiB/GiB)
DISKSPD 2.0.17a 5/01/2016
-S
is expanded to control write-through independent of OS/software cache. Among other things, this allows buffered write-through to be specified (-Sbw
).
- XML: adds a new
element to specify write-through
- XML:
is no longer emitted (still parsed, though), in favor or
and
- Text output: OS/software cache and write-through state are now documented separately (adjacent lines)
- Latency histogram now reports to 9-nines (one part in one billion) in both text and XML output
- Error message added for failure to open write-content source file (
-Z,
)
VM Fleet
VM Fleet is a performance characterization and analyst framework for exploring the storage capabilities of Windows Server Hyper-Converged environments with Storage Spaces Direct.
VM Fleet 2.1.0.0 4/3/2024
- Support for Arc VM management (only applicable to clusters managed by Arc)
Set-FleetRunProfileScript
- produce a free-run script based on one of the defined workload profiles
Watch-FleetCPU
- new support for monitoring guest VCPU utilization (-Guest); can handle data outages
- Fix: performance counter handling now manages intermittent data dropouts (per conventional relog.exe)
- Fix: mid-run vm health check now handles the possibility of many vms taking longer than intended runtime to validate; early exit to avoid false failures
- Fix: ignore reboot required indication from cache layer when changing cache behavior; avoid false failure
VM Fleet 2.0.2.2 12/1/2021
- Fix cluster remoting issue during New-Fleet caused by 2.0.2.1 work
- Use timestamped logging in New-Fleet, simplify and de-colorize default output
VM Fleet 2.0.2.1 11/9/2021
- Fix cluster remoting issues in Move-Fleet and Get-FleetDataDiskEstimate
- Fix timing issue with Start-FleetSweep; always start from fleet pause to avoid triggering free run
- Use uniqueness to guarantee Start-FleetSweep runs profile in case of repeat
VM Fleet 2.0.2 11/2/2021
- Windows Server 2019/RS5 host operation now confirmed & supported
- Read cache warmup for HDD capacity systems should now be faster
Set-FleetPause
will wait for VM responses before completion by default (see -Timeout)
Several minor fixes including:
- Disable Windows Recovery Console in fleet VMs
- Fix:
Show-Fleet
IOPS view now aggregates all VM disk devices
- Fix: clean up leaked/conflicting data collectors and blg automatically
VM Fleet 2.0 9/22/2021
- major release and rewrite as a first class Powershell module
- original script-based VM Fleet remains available at Frameworks/VMFleet1.0
- see the documentation in the Wiki
Source Code
The source code for DiskSpd is hosted on GitHub at:
https://github.com/Microsoft/diskspd
Any issues with DiskSpd can be reported using the following link:
https://github.com/Microsoft/diskspd/issues